Author Archives: admin

ProCal Bias Adjustment

Need a quick refresher on how to make a simple bias adjustment to your Metron analyzer’s calibration? Here is a one minute screen recording to show you how to do it.

Posted in Instrument Calibration, Milk Testing | Comments Off on ProCal Bias Adjustment

ProCal Calibration Video Demo

Here is a short demo of the ProCal calibration software. It shows how a milk analysis data file is opened and regression functions are used to determine adjustments to milk calibration components including fat, protein, lactose and solids non fat. … Continue reading

Posted in Instrument Calibration | Comments Off on ProCal Calibration Video Demo

Opti-I Relative Turbidity Sensor Set-up & Installation

Thanks for your interest in the Opti-I sensor. This video shows how to set up and operate the Opti-I relative turbidity sensor.  

Posted in Opti-I Process Sensor | Tagged , , | Comments Off on Opti-I Relative Turbidity Sensor Set-up & Installation

3 High Reward Opti-I Sensor Locations

The Opti-I offers big benefits in these three typical dairy applications at a modest price: 1. Product transition sensing at key processing points where timers or stopwatches are not preferred, or where automated quality assurance is a necessity. The Opti-I … Continue reading

Posted in Opti-I Process Sensor | Comments Off on 3 High Reward Opti-I Sensor Locations

Milk Component Analysis: A Comparison of Instrumental Methods

Thank you for you interest in this document. Please click on the link below to download the pdf version of the document:¬†Milk Component Analysis: A Comparison of Instrumental Methods. Milk Analysis: A Comparison of Instrumental Methods Milk Component Analysis: A … Continue reading

Posted in Instrumentation Applications, Milk Testing | Comments Off on Milk Component Analysis: A Comparison of Instrumental Methods

CFS Photometer Cuvette Service

If the CFS photometer needs to be disassembled for replacement of the cuvette or if foreign material is trapped in the cuvette, this video shows the procedure on how to complete that task. In most cases, the photometer should be … Continue reading

Posted in Uncategorized | Comments Off on CFS Photometer Cuvette Service

Whey Fat Measurement

The Opti-I can be used as an in line sanitary whey fat measurement instrument. In the lab, a calibration set of raw whey samples were obtained from DQCI (Mounds View, MN). The whey had a range of fat from 0.03 … Continue reading

Posted in Opti-I Process Sensor | Comments Off on Whey Fat Measurement

Milk Analysis

Milk analysis is typically performed by a secondary method that is based upon primary wet chemistry reference data. Milk components commonly determined are fat, protein, lactose and solids. Wet chemistry methods for determination of fat include ether and mojonier. For … Continue reading

Posted in Milk Testing | Comments Off on Milk Analysis

Expressed Breast Milk Research Study

Metron Instruments is partnering in a breast milk research study with the NICU at Metro Health Hospital in Cleveland, Ohio, USA. In the study, the Calais Milk Analyzer provides test results on individual EBM samples for fat, protein, lactose and … Continue reading

Posted in EBM Testing | Comments Off on Expressed Breast Milk Research Study

Metaglas Production Process

The Metaglas sanitary interface used in the Opti-I is the highest quality sanitary interface available. It is a seamless, fused optical window with duplex stainless steel. This graphical video provides a representation of the production process used to make it. … Continue reading

Posted in Opti-I Process Sensor | Comments Off on Metaglas Production Process